Deep Blue BlueFox Basic Provozní pokyny Strana 42

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 41
42
Problem Possible cause Solution
During operation the
alarm box transmits a
short tone sequence.
Power failure Have the mains con-
nection checked by an
approved electrician. See
Safety notes, P. 6.
The PC does not detect
the monitoring bracelet,
or an error message ap-
pears on the PC.
No connection Check the connections
(PC / USB cable / mag-
netic adapter / monitoring
bracelet).
Reset the monitoring
bracelet, see Calling the
status / Clearing the alarm
/ Resetting, P. 35.
Monitoring bracelet:
The LEDs do not illumi-
nate.
The monitoring bracelets
battery is discharged.
See Charging the monitor-
ing bracelet’s battery, P. 31
Monitoring bracelet:
The green LED does not
double ash in the water.
The monitoring bracelet
does not detect water.
Clean the water contacts,
see Maintenance / Service,
P. 41
Monitoring bracelet:
Red double ashes.
Alarm being transmitted
(monitoring bracelet in
the water).
See Alarm (active mode),
P. 28.
Monitoring bracelet:
Red ashes in triple time.
Alarm transmitted,
low battery.
See Alarm (active mode),
P. 28.
Batterie laden, see Charg-
ing the monitoring brace-
let’s battery, P. 31.
Monitoring bracelet:
Red or green ash or
double ash.
Low battery
(monitoring bracelet in
the water).
Charging the battery, see
Charging the monitoring
bracelet’s battery, P. 31.
Monitoring bracelet:
Permanent red
Defective battery Contact a BlueFox dealer.